is leading exporter and supply chain
service provider on medical equipment.
125MA Medical Diagnostic X-ray Machine
MA125 125MA Medical Diagnostic X-ray Machine

Product Type: Conventional diagnostic x-ray
Place of origin: Guangdong
Model No: MA125
Price Terms: FOB Guangzhou
Payment Terms: T/T.L/C.Western Union.MoneyGram
Package: Wooden case
Minimum Order: One set/sets
Delivery Time: 15 days after receive payment
Brand Name: MAYA
MA125 MEDICAL X-RAY MACHINE
 
MA125  Medical  X-ray  Machine 
 
 
Use
Fluoroscopy,Digestive track spot film radiography,General radiography,
Filter-ray device radiography
 
 
Unit Configuration 
Control,HT generator unit,Ht cable,X-ray tube unit,Diagnostic table,Column 
 
 
Main  Characteridtics
1. Single table and single tube
2. Design according to the electric mechanism of middle-size machine ,The function is reasonable
3. The high-tension system is of split structure. Equipped with afullwave rectification high-voltage generator and independent X-ray tube unit, with large output power and reliable and stable operation
4. Supply voltage (V).roentgenoscopy .radiography (kv) and stepless adjust able
5. Equipped with the manostat for filament of X-ray tube and the spacecharge compensator as to ensure the stable and accurate output
6. Equipped with the capacity limitation and portection circuit and Kv mA S interlock limitation and protection
7. Adopt the digial circuit timer. grade according to R10 priority coefficient and can control time exactly.
8. Diagmafic table is of electric back rotation and is equipped with vibrating filter-ray device
9. The spot film device of luminescent serene can hold the film jecket of various sizes and can make the photography of full-film and two sectional films separateiy
10.The column post hast has the bottom track only.which is easy while installation
 
 
Min Technical Indexes

ITEM
CONTENTS
INDEX
Upright post(column)
Moving longitudinally(along the bottom track)
1500mm
landscape orientation movement
360mm
Moving up and down
720-1720mm锛坒rom focus to ground锛
Supply power
Voltage
220V/380Vsingle phase 220V/380V
Frequency
50Hz±0.5Hz
Capacity
10KVA
Intemal resistance
380v:2Ω,220V:0.6Ω
Max DC output voltage
90KV
Max DC output current
100mA
Fluoroscopy
Voltage
50-90KV
current
≤5mA
Radiograph
Voltage
50-90KV
current
Small focus 15mm and big focus30/60/100mA four grades together
spot film
100mA锛坒ixed锛
time
0.04-6.3s,24grades together
High-voltage generator
Capacity
7KVA
X-Ray tube
Model
XD4-2.9/100
Focus
Small focus 1.8mm big focus4.3mm
Diagnostic table
rotary angle
+90°~0~-5°
specification of spot film (stomach and intestines photography)
128×179mm(5"×7")
205×254mm(8"×10")
254×305mm(10"×1")
MAX VOLUME OF RADIOGRAPH
Focus of X-Ray tube
Radiograph mA
Max Radiograph KV
Max exposure time allow
Small focus
15mA
90KV
6.3S
Large focus
30mA
90KV
6.3S
60mA
90KV
6.3S
100mA
85KV
2.5S
125mA
82 KV
1.0S

 Note: We will not make another notice if the contour of product and technical parameters will be changed

 
 MA125B 125MA Radiography X-ray Unit MA200A 200MA Radiography X-ray Equipment