is leading exporter and supply chain
service provider on medical equipment.
MA560B3-1 Medical Anesthesia Respirator
MA560B3-1 Medical Anesthesia Respirator

Product Type: Anesthesia and ventilator Machine
Place of origin: Guangdong
Model No: MA560B3-1
Price Terms: FOB Guangzhou
Payment Terms: T/T.L/C.Western Union.MoneyGram
Package: Carton
Minimum Order: one piece/pieces
Delivery Time: 15 days after receive payment
Brand Name: MAYA

 

MA560B3-1 Anesthesia Machine
 
MA560B3-1 Anesthesia Machine
MA560B3-1 Anesthesia Machine
 

鈻燤ain body High-strength engineering plastic rack, light,
beautiful and corrosion resistant
鈻燬cope of application adult, child
鈻燝as source O2: 0.27锝0.55MPa N2O: 0.27锝0.55MPa
鈻燜low meter O2: 0.1锝1.0L/min 1.1锝10L/min
N20: 0.1锝1.0L/min 1.1锝10L/min
鈻燨2, N2O linkage and N2O Stopper
When using nitrous oxide, oxygen concentration>25%;
When the oxygen pressure<0.2Kpa, the flow of nitrous oxide would be cut off.
鈻燜low rate of rapid oxygen supply 25锝75L/min
鈻燣ow oxygen pressure alarm There will be sound alarm when the oxygen pressure < 0.2MPa
鈻燰aporizer it has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0锝5 vol%. Among Halothane锛孍nflurane, Isoflurane and Sevoflurane, one can be chosen for application as required by the customer. And vaporizers that are imported with original packaging are also available.
鈻燫espiratory circuit working mode: all-close, semi-close, semi-open
releasing pressure: 0.5锝7 kPa
鈻 Respiratory Bellows bellows for adults, bellows for children
tidal volume range:0锝1,500 ml
Ventilator
鈻燚isplay mode High-definition TFT color LCD screen display
鈻燰entilation mode IPPV, SIPPV, SIMV, PEEP, MANUAL,
SIGH, 锛圛MV, VCV, PCV锛
鈻 Ventilation parameters Tidal volume 50锝1500 ml (20锝1500 ml)
Rate 1锝99 bpm
SIMV rate 2锝20 bpm
I:E 2:1锝1:8 (4:1锝1:8)
Inspiratory trigger pressure -1.0锝2.0Kpa
PEEP 0锝2.0Kpa
Pressure Range 1.0锝6.0Kpa
SIGH 1.5 times the inspiratory time (70-150 adjustable)
Inspiratory platform 0锝50%
鈻 Parameters for ventilation monitoring tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, average pressure, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure, Inspiratory platform (autonomous inspiratory rate, lung compliance, airway resistance,flow
-volume oop,pressure-volume loop)
鈻燤onitoring of oxygen concentration 21%锝100%
鈻燬ecurity Alarm System
Oxygen Concentration alarm upper limit setting range 21%锝100%
low limit setting range 10%锝80%
Airway pressure alarm upper limit setting range 0.3锝6.0 kPa
low limit setting range 0.2锝5.0 kPa
Per-minute ventilation volume alarm upper limit setting range 3.0锝30L/min
low limit setting range 1.0锝10L/min
Sustained high-pressure alarm it will give alarm when stress have consistently been higher than 2.5 kPa
Suffocation alarm it will give sound and light alarm if there
is no tidal volume input for 15 seconds
Power alarm
鈻 Power AC 220V±10% 50Hz±1Hz
锛圲PS, Storage battery锛
鈻狅紙Mechanical Arms锛
鈻狅紙End-expiratory CO2 monitoring锛

锛奍tems within brackets are optional.
 

MA560B2 Adult and Child Anesthesia Respirator MA560B4 Anesthesia Respirator
Recommended Products

Contact Us

  • Room 607, No.1 Yingbin Building,Shangjiao,Dashi Town,Panyu Area,Guangzhou,China
  • Tel:86-20--39160381/ 39154381
    Fax:86-20-84597079
    Mobile:86-18925044116
  • webmaster@medicalequipment168.com
    nancy@medicalequipment168.com
  • nancy@bultrasound.com