CCD Ceiling Suspension Digital X-ray Radiography System
MADR003 CCD Ceiling Suspension Digital X-ray Radiography Sy

Product Type: Digital Radiography
Place of origin: Guangdong
Model No: MADR003
Price Terms: FOB Guangzhou
Payment Terms: T/T.L/C.Western Union
Package: Wooden case
Minimum Order: 1 set/sets
Delivery Time: 15 days after receive payment
Brand Name: MAYA

 Product Description

Ceiling Suspension Digital X-ray Radiography System(CCD-DR); Generator: 50KW, 0.1-630mAs;

 Tube: 0.6/1.5MM, 40-125KV(standard); 0.6/1.2MM, 40-150KV(optional); 

Detector: 17 x 17 inch, 9.8 megapixel(standard), 16.8 megapixel(optional); 

AEC(Automatic Exposure System): Measure the dose of X-ray used in real time operation within the Medical Radiology, Oncology and Chiropractors; 

One Button Hand Brake: Doctors only need to press hand brake down and then all the exposure 

terms are automatically finished.


                                                           Specifications


                                                              Generator

CPI High Frequency High Voltage Generator

Made in Canada

Power

50KW

Frequency

100KHZ

Photography (mAS)

0.1-630mAs

Photography (KV)

40-150KV


                                                           Tube

Toshiba Tube (Standard configuration)

Made in Japan

Focus

0. 6/1.5MM

Photography (KV)

40-125KV

Heat Capacity

200KHU

VARIAN RAD-14 Tube (Optional)

Made in U.S.A

Focus

0. 6/1.2MM

Photography (KV)

40-150KV

Heat Capacity

300KHU


                                                         CCD Detector

Image Size

17 x 17 inch

Imaging Time

≤ 10 S

Transmission Time

≤ 2 S

A/D Conversion

16 bit/65535 degree

Image pixels

≥ 9 Megapixel

Limiting resolution

3.4 LP/MM

Kodak CCD Chip

Made in U.S.A

Conversion Screen

CsI 

Refrigeration

Semi-conductor 

Service life

Theoretically there is no life limit


                                         AEC (Automatic Exposure Control System)(optional)         

Number of measuring fields 

3


                                                                          Grid

JPI Grid

Made in Korea

Type 

Stationary

Size

18″×18

Grid ratio

8:1

Density

70L/cm

Focus

130cm


                                                                        Collimator

DS Collimator

Made in Korea

Operation method

Manual

Vision

square

Indicator light time limit

30 seconds±20%

                                                                           

                                           Ceiling Suspension Radiography Stand

Type 

Motor-driven

Vertical movement distance

150cm±5cm, adjustable continuously

Lateral movement distance 

180cm±5cm, adjustable continuously

Longitudinal movement distance

250±5cm

Rotation around vertical rotation axes

(0-360)°±2°

Rotation around horizontal axes

(0-±120)°±2°



                                                       Vertical Stand

Type

Motor-driven

Up-and-down moving range

120cm±5cm

Rotation angle 

(0- +90)°±2°


                                                              Table

Length

200cm(±3 cm)

Height

70cm(±3 cm)

Width

65cm(±3 cm)

Locking mode

mechanical locking

Aluminium equivalent

< 1.7mmAl


                                 Dell Image Capture & Processing Workstation

Lowest standard configuration
 

Core Duo 2.5GHz, 2GB RAM, Hard disk 320GB, 
19 inch LED (1 set), 100M network interface, 
DICOM3.0 interface.


                                    Automatic Exposure Image- Capture Software System

One button hand brake 

Doctors only need to press hand brake down 
and then all the exposure terms are 
automatically finished.


                                          Image Capture & Processing Software

Multifunctional:
Manual /automatic window width / window level, preset window width / window   
  level, positive and negative image turning, image turning, image rotation, image  
  amplification and roaming, labeling and measuring, splitting, automatic electron 
  cutting, part amplification, recovering original image.

Image Processing Technique:
a) Dynamic scope optimization technique
b) High frequency image enhancement technique
c) Noise suppression technique automatically
d) Edge enhancement technique    


                                                   Image Printing Function

Manually selecting the target image for printing;
Different printing devices, film format and printing pages available;
DICOME3.0: @Print SCU; @Worklist SCU; @Storage SCU; @QR SCU; @MPPS SCU.

 

 

CCD Ceiling Suspension Digital X-ray Radiography System
 
MADR002 CCD Based Uc-Arm Digital X-ray Machine (32KW) Flat Panel Detector Based Uc-Arm Digital X-ray Radiography S
Recommended Products

Contact Us

  • Room 607, No.1 Yingbin Building,Shangjiao,Dashi Town,Panyu Area,Guangzhou,China
  • Tel:86-20--39160381/ 39154381
    Fax:86-20-84597079
    Mobile:86-18925044116
  • webmaster@medicalequipment168.com
    nancy@medicalequipment168.com
  • nancy@bultrasound.com